Floating Production Intelligence

Floating Production Intelligence

Safeguarding Against Safety Concern on FLNG Installations

September 14, 2015

Floating Production Intelligence LLC.

Press release - Accidental release of cryogenic liquids such as liquefied natural gas (LNG) poses a significant risk to personnel and assets on oil and gas installations. In addressing these risks, Lloyd’s Register Energy has developed a guidance note that provides a consistent methodology to establish cryogenic exposure.


Lloyd’s Register Energy’s newly launched guidance note provides a methodology to establish risk-based cryogenic exposure based on a probabilistic approach. It is applicable to any unit where hydrocarbon and refrigerant cryogenic hazards are relevant, but offers special guidelines on how to handle leak scenarios specific to LNG plants.


Joar Dalheim, Vice President Technology in Lloyd’s Register Energy’s consulting team said, “As natural gas is becoming increasingly important to satisfy global energy demands, so is the need for safer and more efficient facilities. Given the large quantities of cryogenic materials present on a floating LNG facility, there is a serious risk of extensive damage in the event of cryogenic failure of critical components. As the estimation methods currently available are granular, we see a need for a more inclusive approach. This is what we are delivering with our guidance note.”


The guidance note describes two different methods for cryogenic risk quantification: the initial cryogenic risk analysis (ICRA) and the advanced cryogenic risk analysis (ACRA).


The ICRA method relies on 2D models to estimate cryogenic liquid and vapour hazard zones. While this is the most common approach, it offers certain limitations as it cannot incorporate platform specifics, such as equipment, walls, deck and other structures, and thus necessitates strong conservative assumptions. The ICRA is therefore mainly suitable for cryogenic risk quantification at the early design stages.


The more advanced ACRA risk method is based on 3D computational fluid dynamics (CFD) models and has been developed to incorporate detailed facility specifics (e.g. confinement and congestion) in the risk assessments.


“Integrating 3D analytical tools in the cryogenic risk analysis removes many of the uncertainties and limitations involved when relying on 2D analyses alone. This increases the accuracy of the hazard predictions and eliminates the need for arbitrary assumptions” ascertains Dalheim.


Lloyd’s Register Energy’s services associated with cryogenic spill analysis adapt to the client needs and select the consequence tools most appropriate for the different project phases.


The guidance on cryogenic spills is the latest offering in Lloyd’s Register Energy’s suite of guidance notes on risk-based methodologies. These risk-based analysis guidance notes provide risk-based methodologies to establish explosion, collisions, fire and cryogenic loads based on a probabilistic approach, rather than a worst case scenario with the objective of minimising risk, improving safety, quality and performance.

 

Floating Production Intelligence

  • Annual five year outlook and forecast FPSO database - The online database is updated every day – with information direct from primary sources. In the database are details for 200+planned projects, 390+ installations in service, 40+ floaters on order and 40+ floaters available. The database is fully searchable. Customized charts and spreadsheets can be directly produced from the database. Data are easily exported to excel spreadsheet.

Order Now!

Request a Demo